Instruments for which Setup Files are Available

Ashtech G12 GPS Board | Desoutter Torque Tester TMP220 | ECOM flue gas analyser | Furuno sonar | Garmin GPSmap 168s | Mettler Toledo pH transmitter | Mettler Toledo PB-S laboratory scales | Molytek 2702 data logger | OMRON plc | On Board Diagnostic System | Orbital Science OBIU with Motorola GPS | Parallax BASIC Stamp with DS1620 temperature sensor | Quadra Check 2000 | Sartorius balance | Sylvac Dial Gauge | Telegan Tempest 100 flue gas analyser | Thermo/Orion 290A+ (pH/mV/ISE meter) | Transcell Digital Indicator


Minimise Installation Time: Download Instrument Setup Files

If you are a subscriber to Monitor, our free data acquisition newsletter, you can download Windmill 4.3 for free! This free software package includes LabIML, a universal driver for serial instruments. With Windmill and LabIML you can connect almost any ASCII instrument with an RS232 serial port, to Windows software like Excel. Windmill also includes free logging, charting and output control programs.

When you are configuring your serial instrument, you will need to tell Windmill the settings recommended by your manufacturer. You then save these settings in a file. It may be that someone has already used your make of instrument with Windmill, and so has saved the correct settings. With their setting files you can be instantly up and running. To this end we're compiling a setup library. If you would like to contribute please fill in the form at the bottom of this page.


Setup File Library

Select a zip file and save to disk. Unzip the setup files into your Windmill folder.

Each instrument has an *.aid file. This contains its message transmitting and decoding settings. The download might also include a *.ims file. This contains details such as channel names, engineering units and measurement type. To load the files follow the instructions in the readme.txt file.

Should you have any problems downloading and using the files, please see our FAQ.

Make and Model of Instrument

Setup Files
Select a zip file and save to disk.
Unzip the setup files into your Windmill folder.

Ashtech G12 GPS Board
Step-by-step instructions to connect GPS receivers to Laptops are on our GPS page.
ashg12.zip
Desoutter Torque Tester TMP220
Use a RS232 cable without pin-6 (+15V from TMP220). The instrument sends data when pressing the reset button.
torque.zip
ECOM flue gas analyser
ecom.zip
Furuno sonar
sonar.zip
Garmin GPSmap 168s
Step-by-step instructions to connect Garmin GPS receivers to PCs are on our Garmin GPS page. For
gps168s.zip
Mettler Toledo 1140X pH transmitter
With a few changes can be used with other Mettler Toledo pH transmitters and the Mettler Toledo MC226 Conductivity Meter.
ph1140x.zip
Mettler Toledo PB-S laboratory scales
Should work with other Mettler Toledo balances. Step-by-step instructions are on our Mettler Toledo Balance page.
pbs.zip
Molytek 2702 data logger
For more details of using Windmill with Molytek data loggers, see our case study.
molytek.zip
OMRON plc
The driver can transmit data bits from the PLC to the computer so it is in effect a digital driver. It should also be possible to read registers from the PLC.
omron.zip
On Board Diagnostic System: OBD
The driver can transmit data bits from the PLC to the computer so it is in effect a digital driver. For more details of On Board Diagnostics, see our OBD page.
obd.zip
Orbital Science OBIU with Motorola OnCore GPS receiver
Step-by-step instructions to connect GPS receivers to Laptops are on our GPS page.
gps.zip
Parallax BASIC Stamp with DS1620 temperature sensor
Step-by-step instructions are provided on the OSTEC site.
stamp.zip
Quadra Check 2000
Also includes Excel and DDE examples - see our Quadra Check page for full details.
quadra20.zip
Sartorius Balance
Step-by-step instructions are on our Sartorius Balance page.
sartorius.zip
Sylvac Dial Gauge
Step-by-step instructions are on our Sylvac Dial Gauge page.
sylvac.zip
Telegan Tempest 100 flue gas analyser telegan.zip
Thermo/Orion 290A+ (pH/mV/ISE meter)
For this example, the meter was set to print the reading every 5 seconds with Windmill running in continuous flow/background mode.
orion.zip
Transcell Digital Indicator
This example assumes you are using the Transcell in Simplex mode. For more information, or for details of using the Transcell in Duplex mode, see our Transcell Digital Indicator page
transcell.zip

Please send us your Setup Files

To expand this free library we need your setup files. The files are text files and only contain information about your instrument. They contain nothing that can identify you, nor anything else about your system. If you wish we're happy to place a link back to your web site in the library, as an acknowledgement of your contribution. You can either fill in this form, or e-mail us the files. Please send your *.aid file and, optionally, your *.ims file (both found in your Windmill folder).

Make and model of instrument:


Open the files in Notepad (or similar) 
then copy the contents here:
     AID File                    IMS File
  

If your RS232 lead is non-standard please let us know:


Other comments, tips or suggestions:

Name:        
Organisation:
Email:       

Home | Windmill Programs | Monitor | On-Line Shop | Free Literature and Software Demos | Contents | Search

Copyright Windmill Software Ltd 2001
PO Box 58, North District Office, Manchester, M8 8QR, UK.
E-mail, Tel: +44 161 833 2782
http://www.windmill.co.uk/library.html
Data Acquisition News Feed (RSS) Free measurement news feed...
Designed by Studholme.net
Related Topics: